Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add filters








Type of study
Year range
1.
Arq. bras. med. vet. zootec. (Online) ; 72(5): 1742-1750, Sept.-Oct. 2020. tab, ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1131554

ABSTRACT

Objetivou-se, com este estudo, avaliar o processo de cicatrização da musculatura reto-abdominal em coelhos submetidos à laparorrafia, utilizando-se o fio de sutura à base de quitosana, comparando-o aos fios de categute cromado e poliglactina 910. Foram utilizados 24 coelhos adultos, divididos aleatoriamente em quatro grupos: quitosana e categute 15 dias (QC-15dias), quitosana e categute 30 dias (QC-30 dias), quitosana e poliglactina 910 15 dias (QP-15 dias) e quitosana e poliglactina 910 30 dias (QP-30 dias). Cada grupo foi composto por seis coelhos, nos quais foram realizadas duas incisões, uma do lado direito e outra do lado esquerdo e, posteriormente, a laparorrafia, com o fio de quitosana de um lado e o categute cromado ou poliglactina 910 do outro. Realizou-se análise clínico-cirúrgica, histológica e avaliação de achados de necropsia, além de testes de citotoxicidade e de mecânica no fio de quitosana. Ele apresentou baixa resistência mecânica e citotóxica. O fio de quitosana não proporcionou uma cicatrização satisfatória em coelhos, pois desencadeou uma resposta inflamatória acentuada.(AU)


The objective of this study was to evaluate the healing process of the recto-abdominal muscles in rabbits submitted to laparorrhaphy using chitosan-based suture yarn, comparing it to chrome catgut and polyglactin 910 yarns. Twenty-four adult rabbits were divided in to four random groups: chitosan and polyglactin 910 15 days (QP-15 days) and chitosan and polyglactin 910 30 days (QC-30 days), chitosan and polyglactin 910 15 days (QP-15 days) QP-30 days). Each group consisted of six rabbits, in which two incisions were made, one on the right side and one on the left side, and later the laparorraphy with the chitosan yarn on one side and chromed catgut or polyglactin 910 on the other. Clinical-surgical, histological and necropsy findings were evaluated, as well as cytotoxicity and mechanical tests on the chitosan wire. It presented low mechanical and cytotoxic resistance. Chitosan thread did not provide satisfactory healing in rabbits, as it triggered a marked inflammatory response.(AU)


Subject(s)
Animals , Rabbits , Polyglactin 910/analysis , Sutures/veterinary , Wound Healing , Catgut/veterinary , Chitosan , Rectum/surgery , Suture Techniques/veterinary , Laparoscopy/veterinary , Guided Tissue Regeneration/veterinary , Abdomen/surgery
2.
Arq. bras. med. vet. zootec. (Online) ; 69(4): 807-814, jul.-ago. 2017. ilus, tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-876516

ABSTRACT

As lesões traumáticas dos membros que resultam em secções tendíneas são problemas comuns na clínica equina. Diversas complicações têm sido associadas à reparação dos tendões nessa espécie. O objetivo do presente trabalho foi avaliar biomecanicamente dois padrões de sutura e dois diferentes materiais aplicados às tenorrafias. Vinte e quatro peças de tendão flexor digital profundo de equinos foram seccionadas e suturadas em padrão locking loop duplo (grupo 1, com polipropileno; grupo 2, com poliglactina) ou em padrão locking loop simples associado à sutura de epitendão (grupo 3, com polipropileno; grupo 4, com poliglactina). Os corpos de prova foram submetidos a ensaios mecânicos de tração, em que se determinaram valores de força mínima, força máxima e pico de força, além do afastamento observado entre os cotos durante o pico máximo de força. Para avaliação dos resultados, foram utilizados os métodos ANOVA e os não paramétricos de Kruskal-Wallis e Mann-Whitney (P<0,05). Os maiores valores de força máxima foram documentados no grupo 3. Os valores de força mínima foram maiores nos grupos 3 e 4 que nos grupos 1 e 2, mas não diferiram significativamente entre os grupos 3 e 4. Os valores de pico de força foram maiores nos grupos 1 e 2 que no grupo 4, mas não diferiram significativamente no grupo 3. O afastamento foi maior nos grupos 1 e 2 quando comparados aos grupos 3 e 4. O padrão locking loop simples, com sutura de epitendão, atingiu maior resistência quando avaliado afastamento de até 3 milímetros entre os cotos tendíneos, sendo considerado padrão de escolha para aplicação clínica, tendo em vista os resultados obtidos neste trabalho.(AU)


Traumatic distal limb injuries resulting in tendon rupture are common in equine practice. Several complications have been associated with tendon repair in horses. The aim of this study was to compare the biomechanical properties of two tenorrhaphy techniques using two different suture materials. Twenty-four equine deep digital flexor tendon specimens were transected and sutured with the double locking loop pattern (polypropylene, group 1; polyglactin, group 2) or the single locking loop pattern with peripheral epitendon suture (polypropylene, group 3; polyglactin, group 4). Specimens were submitted to mechanical strain testing. Maximum, minimum and peak strain, and maximum, minimum and peak gap formation were evaluated. ANOVA and the non-parametric Kruskal-Wallis and Mann-Whitney tests were used (P<0.05). Higher maximum strength values were documented in group 3. Minimum strength values were higher in groups 3 and 4 than 1 and 2, but did not differ significantly between groups 3 and 4. Peak strength values were higher in groups 1 and 2 than 4, but did not differ significantly from group 3. Gap formation was greater in groups 1 and 2 than 3 and 4. The single locking loop pattern with epitendon suture performed with polypropylene had greater resilience, yielded lesser gap formation (3 mm) and is the pattern of choice for clinical application based on the results of this study.(AU)


Subject(s)
Animals , Horses/surgery , Mechanical Phenomena , Suture Techniques/veterinary , Sutures/veterinary , Tendons/surgery
3.
Int. j. morphol ; 28(4): 1221-1225, dic. 2010. ilus
Article in English | LILACS | ID: lil-582914

ABSTRACT

The gross and histologic patterns of abdominal adhesions formed by the use of chromic catgut and polypropylene suture materials were evaluated in dogs. Gross and histologic examinations did not reveal significant difference (p>0.05) in the degree of adhesions observed at enteropexy sites in both suture materials. The use of polypropylene with superior suture qualities should be considered instead of chromic catgut for procedures in which adhesion is desired in the dog.


Fueron evaluados los patrones macroscópicos e histológicos de las adherencias abdominales formadas por el uso de catgut crómico y materiales de sutura de polipropileno. Los exámenes macroscópicos e histológicos no revelaron diferencias significativas (p> 0,05) en el grado de adherencias observadas en los sitios de la enteropexia en ambos materiales de sutura. El uso de suturas de polipropileno con mejores cualidades debe ser considerado en lugar del catgut cromado para procedimientos en los que la adherencia en el perro es deseada.


Subject(s)
Male , Animals , Female , Dogs , Tissue Adhesions/etiology , Catgut/adverse effects , Dog Diseases/pathology , Polypropylenes/adverse effects , Sutures/veterinary , Abdomen/surgery , Tissue Adhesions/pathology , Severity of Illness Index
4.
Braz. j. vet. res. anim. sci ; 42(5): 357-366, 2005. ilus, tab
Article in Portuguese | LILACS | ID: lil-433205

ABSTRACT

O objetivo deste estudo foi realizar um estudo experimental comparando-se sob o ponto de vista anatomopatológico as suturas manual e mecânica em brônquio principal após pneumonectomia esquerda em cães. Foram utilizados 18 cães, sadios, machos e fêmeas, adultos, sem raça definida, pesando entre 9 e 27,5 kg. Foram separados em 2 grupos de 9 cães, de acordo com o tipo de sutura empregada: Grupo A - sutura manual com fio polipropileno 5-0; Grupo B sutura mecânica com grampeador mecânico modelo TL- 30. Cada grupo foi subdividido em 3 subgrupos de 3 animais, sendo estabelecido estudo temporal aos 7, 15 e 36 dias de pós-operatório, onde foi realizada avaliação anatomopatológica da cicatrização das suturas manual e mecânica. Na avaliação histopatológica foram avaliados, qualitativamente e semi-quantitativamente, intensidade da inflamação, fibrose, vasos neoformados e presença ou não de tecido de granulação, granuloma tipo corpo estranho e necrose. Os resultados encontrados foram analisados estatisticamente. Com relação à análise rustopatológica, ocorreu a formação de granuloma tipo corpo estranho no coto brônquico esquerdo em 88,9% dos cães submetidos à sutura manual e em nenhum dos cães submetidos à sutura mecânica. Houve, ainda, diferença estatística significativa nos cães dos Grupos A e B em relação à intensidade da inflamação, sendo de maior intensidade nos cães submetidos à sutura manual. Concluiu-se que os 2 tipos de sutura promoveram cicatrização adequada do coto brônquico principal esquerdo, embora tenha ocorrido maior intensidade de inflamação e maior ocorrência de granuloma tipo corpo estranho nos cães submetidos à sutura manual.


Subject(s)
Animals , Male , Female , Bronchi/anatomy & histology , Bronchi/surgery , Dogs , Pneumonectomy/veterinary , Sutures/veterinary
5.
Braz. j. vet. res. anim. sci ; 32(4): 241-5, 1995. ilus
Article in Portuguese | LILACS | ID: lil-240108

ABSTRACT

Compararam-se fios de sutura absorvíveis sintéticos. Estudaram-se o Dexon Plus e o Maxon com enterorrafias ileais em cäes. As investigaçöes foram conduzidas em 9 animais e os protocolos de avaliaçäo compreenderam estudos macro e microscópicos aos 2, 10 e 30 dias de pós-operatório. Os resultados evidenciaram aos 2 dias de pós-operatório que, comparativamente ao Maxon, o Dexon Plus contribuiu com a ocorrência de significativo infiltrado de polimorfonucleares neutrófilos e áreas de necrose. Aos 10 dias evidenciou-se, comparativamente ao Maxon, que o infiltrado celular apresentou acentuada diminuiçäo, com substituiçäo por mononucleares e fibroblastos jovens, tendendo à organizaçäo. A despeito das diferenças vistas nas fases inicial e intermediária, na tardia os achados mostraram-se similares para ambos os materiais. Houve diminuiçäo marcante do quadro inflamatório, intensa proliferaçäo fibroblástica e tendência à formaçäo de "granulomas de corpo estranho".


Subject(s)
Animals , Polyglycolic Acid/pharmacokinetics , Dogs/surgery , Wound Healing , Ileum/surgery , Intestines/surgery , Sutures/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL